High efficiency once-through boiler

High efficiency once-through boiler SEN-CS Series SEN-300CS/400CS/500CS/600CS/800CS/1000CS/1500CS/2000CS/2500CS/3000CS
This is a high-quality, high-efficiency boiler manufactured with optimal design and strict quality control.
- Product Features
-
- High efficiency is achieved by installing a specially processed, pressurized, high-performance water preheater in the main body, which is designed with an efficient two-row water pipe arrangement of a unique structure.
- This is a high-efficiency boiler that reduces heat loss by absorbing as much of the high-temperature exhaust gas heat generated after combustion as possible in a high-performance feedwater preheater, resulting in significant savings in fuel costs.
- By adopting a fully automated method, water supply, operation, and burner combustion devices are automatically controlled with a single switch, and various safety devices are attached so anyone can use it with confidence.
- When equipped with the artificial intelligence control device SE-Ai system, operation and maintenance become easier. (Optional)
Product standard specifications performance table
Item\Type | Unit | SEN-300CS | SEN-400CS | SEN-500CS | SEN-600CS | SEN-800CS | SEN-1000CS | SEN-1500CS | SEN-2000CS | SEN-2500CS | SEN-3000CS | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated evaporation amount | kg/hr | 300 | 400 | 500 | 600 | 800 | 1000 | 1500 | 1700 | 2500 | 3000 | |
Max. operating pressure | Mpa | 1 (10kg/㎠) | ||||||||||
Heat output | MW | 0.22 | 0.3 | 0.37 | 0.45 | 0.6 | 0.75 | 1.12 | 1.87 | 2.25 | 2.25 | |
kcal/h | 193,110 | 257,480 | 321,850 | 386,220 | 514,960 | 643,700 | 965,550 | 1,287,400 | 1,609,250 | 1,931,100 | ||
Thermal efficiency | % | above 95% | ||||||||||
Heat transfer area | ㎡ | 4.9 | 4.95 | 4.99 | 9.7 | 9.8 | 9.9 | 9.99 | 25.4 | 29.8 | 36 | |
Quantity held | ℓ | 96 | 112 | 148 | 176 | 188 | 220 | 290 | 390 | 470 | 490 | |
Product weight | kg | 870 | 1210 | 1580 | 1920 | 2320 | 2780 | 2980 | 3900 | 4300 | 4800 | |
Power used | V | 220V×3Ø / 380V×3Ø×4W | ||||||||||
Electrical capacity | Blower motor | kw | 0.4 | 0.45 | 0.45 | 2.2 | 2.2 | 3.7 | 5.5 | 11 | 11 | 15 |
Water pump | kw | 0.75 | 1.5 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 3.7 | 3.7 | 3.7 | |
Oil pump | kw | - | - | - | 0.4 | 0.4 | 0.4 | 0.4 | 0.75 | 0.75 | 0.75 | |
Appearance | Width (W) | mm | 950 | 1,060 | 1,060 | 1,360 | 1,360 | 1,420 | 1,420 | 2,320 | 2,320 | 2,530 |
Length (L) | mm | 2,160 | 2,250 | 2,250 | 2,520 | 2,620 | 2,810 | 2,850 | 3,600 | 3,750 | 3,980 | |
Height (H) | mm | 1,920 | 2,050 | 2,150 | 2,250 | 2,340 | 2,430 | 2,480 | 3,150 | 3,250 | 3,320 | |
Combustion method | - | Forced pressure ventilation | ||||||||||
Control method | - | High-Low-Off (3 positions) | ||||||||||
Fuel consumption | Diesel | kg/h | 19.7 | 26.3 | 32.8 | 39.4 | 52.6 | 65.7 | 98.6 | 131.5 | 164.4 | 197.3 |
Boiler kerosene | kg/h | 19.6 | 26.1 | 32.6 | 39.2 | 52.2 | 65.3 | 98 | 130.7 | 163.3 | 196 | |
City gas(13A) | Nm³/h | 20.5 | 27.3 | 34.2 | 41 | 54.7 | 68.4 | 102.6 | 136.8 | 171.1 | 205.3 | |
LPG(Propane) | Nm³/h | 9 | 12.1 | 15.1 | 18.1 | 24.2 | 30.2 | 45.4 | 60.5 | 75.6 | 90.8 | |
kg/h | 18.3 | 24.4 | 30.5 | 36.6 | 48.9 | 61.1 | 91.7 | 122.3 | 152.8 | 183.4 | ||
LPG(Butane) | Nm³/h | 7.1 | 9.5 | 11.9 | 14.3 | 19 | 23.8 | 35.7 | 47.7 | 59.6 | 71.5 | |
kg/h | 18.5 | 24.7 | 30.9 | 37.1 | 49.5 | 61.9 | 92.9 | 123.9 | 154.9 | 185.9 | ||
Connection diameter | Steam outlet | A | 32 | 32 | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 100 |
Water inlet | A | 20 | 25 | 25 | 25 | 25 | 25 | 25 | 32 | 32 | 32 | |
Drain | A | 25 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | |
Safety valve | A | 25(low) | 32(low) | 32(low) | 40(low) | 25(low) | 25(low) | 32(low) | 32(low) | 40(low) | 40(low) | |
Fueling port | A | 15 | 15 | 15 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | |
Fuel gas inlet | A | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | |
Flue | Ømm | 200 | 250 | 250 | 250 | 300 | 300 | 350 | 400 | 450 | 500 |
The above specification performance table is based on the following :
- Steam pressure 0.7MPa[7kg/㎠], steam enthalpy 2.76MJ/kg[660.8kcal/kg], water temperature 293˚k(20˚C)
- Low calorific value of fuel
- Diesel : 43.12MJ/kg (10,300kcal/kg)
- Boiler kerosene : 43.4MJ/kg (10,368kcal/kg)
- City gas(13A) : 41.45MJ/Nm3 (9,900kcal/Nm3)
- This specification performance table may be changed without notice for quality improvement.